Description

Features:
. Full range AC input
. Withstands 300vac surge input for 5 seconds
. No-load power consumption <0 .3W
. Small size, 1U low profile
. Operating temperature up to 70C
. Protection: Short circuit / overload / overvoltage . Natural air cooling
. Conforms to IEC/ BS EN/ EN 60335-1 ( PD3) and IEC/ BS EN/ EN61558- 1 , 2- 16 for appliance applications .
. 5,000 m above sea level .
. 5G vibration test
. High efficiency, longevity and reliability
. Power on LED indicator .
. Overvoltage class III
. 100% full load aging test
. 3-year warranty

Applications:
‧ Industrial automation machinery
‧ Industrial control systems
‧ Mechanical and electrical equipment
‧ Electronic apparatus, equipment and devices
‧ Household appliances

The LZI-50 series is a 50W single output enclosed power supply with a 30mm low profile design and a full range of AC inputs from 90 to 264VAC. The whole series is available in 5V, 12V and 24V outputs.
In addition to an efficiency of 89%, the metal mesh housing design enhances heat dissipation and allows the The LZI-50 to operate without a fan in the -30C to +70C temperature range. The The LZI-50 is fully protected and resistant to 5G vibration; it complies with TUV BS EN/EN62368-1 ,BS EN/EN60335-1 ,BS EN/EN61558-1/-2-16 ,UL62368-1 and GB4943 international safety regulations. GB4943 international safety regulations, the The LZI-50 series offers a cost effective solution for a variety of industrial applications.

Model:LZI-50-12-0416

Output
DC voltage 12V
Rated current 4.16A
Current range 0 ~ 4.16A
Power rating 50W
Ripple and noise (max) 120mVp-p
Voltage adjustment range 10.2 ~ 13.8V
Voltage accuracy ±1.0%
Linear adjustment rate ±0.5%
Load Adjustment Rate ±0.5%
Start-up, rise time 1000ms, 30ms/230VAC       2000ms,30ms/115VAC at full load
Holding time(Typ.) 30ms/230VAC     12ms/ 115VAC at full load
Input
Voltage range 90 ~ 264VAC
Frequency range 47 ~ 63Hz
Efficiency(Typ.) 86%
AC current(Typ.) 0.95A/115VAC        0.56A/230VAC
Inrush current(Typ.) Cold start45A/230VAC
Leakage current <0.75mA / 240VAC
Protection
Overload 110 ~ 150% of rated output power
Protection mode: Hiccup mode, automatic recovery when abnormal conditions are removed
Overvoltage 13.8 ~ 16.2V
Protection mode: shutdown of output voltage, restart recovery
Environment
Operating temperature -30 ~ +70C  ((Please refer to “Derogation Curve”))
Operating humidity 20 ~ 90% RH,Non-condensing
Storage temperature, humidity -40 ~ +85C, 10 ~ 95% RH,Non-condensing
Temperature coefficient ±0.03%/C (0 ~ 50C)
Safety and electromagnetic compatibility
Vibration resistant 10 ~ 500Hz, 5G 10 min/cycle, 60 min each X, Y, Z
Overvoltage rating III; according to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 m
Safety norms UL62368- 1 , TUV BS EN/EN62368- 1 , BS EN/EN60335- 1 , BS EN/EN61558- 1/-2- 16 ,CCC GB4943 . 1 , BSMI CNS15598- 1 ,EAC TP TC 004 , AS/NZS 60950 . 1(by CB) ,
Pressure resistance I/P-O/P:4KVAC    I/P-FG:2KVAC   O/P-FG:1.25KVAC
Insulation resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/ 25℃/ 70% RH
Electromagnetic compatibility emissions Conforms to BS EN/ EN55032 (CISPR32) C lass B , BS EN/ EN55014 , BS EN/ EN61000-3-2 , -3 , GB/T 9254 , BSMI CNS15936 , EAC TP TC 020 , KC KN32 , and
Electromagnetic compatibility immunity Conforms to BS EN/EN61000-4-2,3,4,5,6,8, 11, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN55035, Heavy Industry Standard, EAC TP TC 020, KC KN32.
Other
MTBF 3201.5K hrs min.    Telcordia SR-332 (Bellcore) ; 655.5Khrs min.    MIL-HDBK-217F (25C)
Size 99*82*30mm (L*W*H)
Weight 0.25Kg