Description
Features:
International universal full range AC input
Protection types: short circuit / overload / overvoltage
Natural air cooling
LED power indicator
100% full load aging
All use 1 0 5 C long life electrolytic capacitors
Able to withstand 3 0 0 V A C surge input for 5 seconds
Operating temperature up to 7 0 0 C
Withstands 5 G vibration test
No-load consumption < 0 . 5 W
High efficiency, long life and high reliability
3 year warranty
Model:LZI-120-24-05 |
||||||
| Output | ||||||
| DC voltage | 24V | |||||
| Rated current | 5A | |||||
| Current range | 0 ~ 5A | |||||
| Power rating | 120W | |||||
| Ripple and noise (max) | 120mVp-p | |||||
| Voltage adjustment range | 22.8~26.4 V | |||||
| Voltage accuracy | ±1.0% | |||||
| Linear adjustment rate | ±0.5% | |||||
| Load Adjustment Rate | ±0.5% | |||||
| Start-up, rise time | 500ms, 30ms/230VAC 1200ms,30ms/ 115VAC(At full load) | |||||
| Holding time(Typ.) | 60ms/230VAC 14ms/ 115VAC(At full load) | |||||
| Input | ||||||
| Voltage range | 88 ~ 264VAC | |||||
| Frequency range | 47 ~ 63Hz | |||||
| Efficiency(Typ.) | 86.00% | |||||
| AC current(Typ.) | 2A/ 115VAC 3A/230VAC | |||||
| Inrush current(Typ.) | Cold start:40A/230VAC | |||||
| Leakage current | <2mA/ 240VAC | |||||
| Protection | ||||||
| Overload | 110%~150% of rated output power | |||||
| Protection mode: Hiccup mode, automatic recovery after removal of abnormal load conditions | ||||||
| Overvoltage | 27.6 ~ 32.4V | |||||
| Protection mode: Hiccup mode, automatic recovery when abnormal voltage conditions are removed | ||||||
| Environment | ||||||
| Operating temperature | -25~+70℃ I6:J6 | |||||
| Operating humidity | 20 ~ 90% RH,Non-condensing | |||||
| Storage temperature, humidity | -40 ~ +85℃, 10 ~ 95% RH | |||||
| Temperature coefficient | ±0 .03%/℃ (0 ~ 50℃) | |||||
| Safety and electromagnetic compatibility | ||||||
| Vibration resistant | 10 ~ 500Hz, 5G 10 min/cycle, 60 min each X, Y, Z axis | |||||
| Safety norms | UL62368- 1, TUV BS EN/EN62368- 1, AS/NZS 62368. 1, EAC TP TC 004 approved | |||||
| Pressure resistance | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||
| Insulation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
| Electromagnetic compatibility emissions | Conforms to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | |||||
| Electromagnetic compatibility immunity | Conforms to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), Heavy Industry Standard, EAC TP TC 020 | |||||
| Other | ||||||
| MTBF | 2918.8K hrs min. Telcordia SR-332 (Bellcore) ; 569.6K hrs min. MIL-HDBK-217F (25℃) | |||||
| Size | 159*98*38mm (L*W*H) | |||||
| Weight | 0.3Kg | |||||