Description
Features:
International universal full range AC input
Protection types: short circuit / overload / overvoltage
Natural air cooling
LED power indicator
100% full load aging
All use 1 0 5 C long life electrolytic capacitors
Able to withstand 3 0 0 V A C surge input for 5 seconds
Operating temperature up to 7 0 0 C
Withstands 5 G vibration test
No-load consumption < 0 . 5 W
High efficiency, long life and high reliability
3 year warranty
Model:LZI-120-12-10 |
||||||
Output | ||||||
DC voltage | 12V | |||||
Rated current | 10A | |||||
Current range | 0 ~ 10A | |||||
Power rating | 120W | |||||
Ripple and noise (max) | 120mVp-p | |||||
Voltage adjustment range | 10.8 ~ 13.2V | |||||
Voltage accuracy | ±1.0% | |||||
Linear adjustment rate | ±0.5% | |||||
Load Adjustment Rate | ±0 .5% | |||||
Start-up, rise time | 500ms, 30ms/230VAC 1200ms,30ms/ 115VAC(At full load) | |||||
Holding time(Typ.) | 60ms/230VAC 14ms/ 115VAC(At full load) | |||||
Input | ||||||
Voltage range | 88 ~ 264VAC | |||||
Frequency range | 47 ~ 63Hz | |||||
Efficiency(Typ.) | 83% | |||||
AC current(Typ.) | 2A/ 115VAC 3A/230VAC | |||||
Inrush current(Typ.) | Cold start:40A/230VAC | |||||
Leakage current | <2mA/ 240VAC | |||||
Protection | ||||||
Overload | 110%~150% of rated output power | |||||
Protection mode: Hiccup mode, automatic recovery after removal of abnormal load conditions | ||||||
Overvoltage | 13.8~16.2V | |||||
Protection mode: Hiccup mode, automatic recovery when abnormal voltage conditions are removed | ||||||
Environment | ||||||
Operating temperature | -25~+70℃ (Please refer to “Derogation Curve”) | |||||
Operating humidity | 20 ~ 90% RH,Non-condensing | |||||
Storage temperature, humidity | -40 ~ +85℃, 10 ~ 95% RH | |||||
Temperature coefficient | ±0 .03%/℃ (0 ~ 50℃) | |||||
Safety and electromagnetic compatibility | ||||||
Vibration resistant | 10 ~ 500Hz, 5G 10 min/cycle, 60 min each X, Y, Z axis | |||||
Safety norms | UL62368- 1, TUV BS EN/EN62368- 1, AS/NZS 62368. 1, EAC TP TC 004 approved | |||||
Pressure resistance | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||
Insulation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
Electromagnetic compatibility emissions | Conforms to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | |||||
Electromagnetic compatibility immunity | Conforms to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), Heavy Industry Standard, EAC TP TC 020 | |||||
Other | ||||||
MTBF | 2918.8K hrs min. Telcordia SR-332 (Bellcore) ; 569.6K hrs min. MIL-HDBK-217F (25℃) | |||||
Size | 159*98*38mm (L*W*H) | |||||
Weight | 0.3Kg |